Tramex CRH Moisture Content and Relative Humidity Meter for Flooring
The world`s most advanced Moisture and Relative Humidity Meter for the Flooring Industry
The Tramex CRH measures Moisture Content by the Non-Destructive Method, Relative Humidity by the In-Situ Method (ASTM F2170-02) or Hood method (ASTM F2420-05) and Temperature and Dew Point in concrete and gypsum flooring.
Tramex CRH Moisture Content & RH Meter Benefits:
Measure Moisture Content Non-Destructively in concrete and gypsum flooring.
Measure Relative Humidity using the RH Probe on (hood method) or below (in situ method) the surface.
Measure Ambient Relative Humidity, Temperature and Dew Point with plug-in RH probe. Intelligent RH Probe. (Traceable to NIST national and international standards.)
Tramex CRH Moisture Content & RH Meter Features:
Stores up to 900 recorded readings in 30 files.
Recorded readings can be recalled and displayed on dot matrix LCD.
Download recorded readings to computer for report writing.
Multiple scales to suit different types of floor slabs and screeds.
Operates on time proven impedance measurement principle.
Instant readings on clear digital display.
How does it work?
In Moisture measuring mode , the Tramex CRH uses the principle of electrical impedance measurement to give accurate non-destructive moisture readings in concrete and gypsum floor screeds.
From Electrodes with special spring mounted probes on the base of the instrument, a low frequency signal is transmitted into the material being tested to measure the electrical impedance.
This signal is processed as a percentage of moisture reading for concrete slabs and a relative reading for gypsum screed.
(Relative Humidity Probe, Insitu Sleeves for performing ASTM F2170-02 - Optional )
In Hygrometer mode it uses a solid state capacitive sensor Relative Humidity probe to give accurate and fast relative humidity, temperature & dew point temperature readings.
While being easy and uncomplicated to operate, the Tramex CRH has a powerful micro controller, which processes the information received and accurately calculates the moisture content, relative humidity, temperature and dew point. These readings are displayed on the clear digital display.
The high capacity non-volatile memory chip which stores and retains its data. This information can be recalled at any time by scrolling and reading directly from the instruments own display or downloaded to a PC for storage and inclusion on a spread sheet or report.
The Tramex CRH Identifies Problems Associated with Concrete Moisture
Excessive moisture in concrete floor slabs and screeds can lead to a host of problems in all types of floor coverings such as:
Adhesive degradation
Delaminating of the floor covering from the slab and within itself
Condensation, blistering
Movement and deterioration of the covering.
Mold growth
Most of these problems can be related to the floor covering being installed on a sub floor that is not sufficiently dry. It is therefore important to insure that the floor slab or screed is sufficiently dry enough to accept a covering or coating. Dimension:6"x3"x14" Weight: 0.77lbs
Supplied with: Customized CD
Stored Reading: 900 reading in 30 files
Battery: 9 volt (included)
One year warranty
See "Related Products" Below For Optional Accessories