IAQ Monitor Temperature, Humidity, Carbon Dioxide Alarm
High Accuracy Temperature, Humidity & IAQ Monitor
High Accuracy Temperature, Humidity & IAQ Monitor CDM77232
IAQ monitoring and ventilation control. Ideal for monitoring indoor air quality of houses, offices, classrooms, factories, hospitals and hotels. Includes relay for activating a ventilation system.
High Accuracy Temperature, Humidity & IAQ Monitor Features:
- Measures ambient temperature, relative humidity (RH), dew point and wet bulb temperatures, and CO2 level
- Backlit LCD displays ambient temperature, RH and CO2 level on separate readouts
- Uses stable non-dispersive infrared (NDIR) sensor to measure CO2
- Calculates, periodically updates and displays 8-hr. time-weighted average (TWA) of CO2 exposure and 15-minute short-term exposure limit (STEL)
- Adjustable Hi and Lo audible/visual CO2 alarm levels
- Relay activates/cancels output signal when CO2 level exceeds Hi alarm level/falls below Lo alarm level
- Min/Max memory + data hold
- RS-232 output jack; optional ASFTKIT PC interface/data logging kit includes RS-232 to USB adaptor
- 33% HR33LJ and 75% HR75LJ reference salts are available to calibrate relative humidity (RH) measurement in the field
- Auto power off (can be disabled for calibration)
- Wall or desktop mount
Click Here to See Manufacturer Manual
CDM77232 Specifications:
Ambient temperature measurement range/resolution: 14° to 140°F /0.1
Ambient temperature measurement accuracy: 0.9°F
RH measurement range/resolution: 0 to 99.9%RH/0.1%
RH measurement accuracy: 3% from 10 to 90%RH; 5% elsewhere
CO2 measurement range/resolution: 0 to 5000ppm/1 ppm
CO2 measurement accuracy: (30 ppm + 5% of reading)
CO2 calibration level: 400ppm
CO2 alarm level adjustment range: 100 to 9900 ppm
CO2 alarm relay outputs: 5V (activated); 0V (cancelled)
Warmup time: 30 seconds
Response times: 30 seconds for temperature and CO2; 30 minutes for RH
Auto power off triggering time: 20 minutes of front-panel inactivity
Operating temperature: 32° to 122°F @ <80% RH
Weight: 14 oz.
Power source: AC adaptor (included)
One Year Limited Manufacture's Warranty
-
SKUCDM77232
-
GTIN886007282645
-
ManufacturerGeneral Tools and Instruments
-
Product Weight14 oz.
-
Power SourceAC adaptor (included)
-
Ambient temperature measurement range/resolution14° to 140°F (-10° to 60C)/0.1
-
Ambient temperature measurement accuracy0.9°F (0.6°C)
-
RH measurement range/resolution0 to 99.9%RH/0.1%
-
RH measurement accuracy3% from 10 to 90%RH; 5% elsewhere
-
CO2 measurement range/resolution0 to 5000ppm/1 ppm
-
CO2 measurement accuracy(30 ppm + 5% of reading)
-
CO2 calibration level400ppm
-
CO2 alarm level adjustment range100 to 9900 ppm